Controller Solid State Contactors

Results: 34
Select Image Part # Mfr. Description Datasheet Availability Pricing (IDR) Filter the results in the table by unit price based on your quantity. Qty. RoHS ECAD Model Mounting Style Load Current Rating Load Voltage Rating Control Voltage Range Input Current Minimum Operating Temperature Maximum Operating Temperature Width Height Packaging Series
Omron Automation and Safety Contactors - Solid State 25A 3-phs SSR DIN mt 2 pl 480 4In Stock
Min.: 1
Mult.: 1

DIN Rail Mount 25 A 200 VAC to 280 VAC 12 VDC to 24 VDC 7 mA to 15 mA - 30 C + 80 C G3PE
Crydom Contactors - Solid State 18A 600AC 280A/DC In ZC 3Leg 3phs DINRail 20In Stock
Min.: 1
Mult.: 1

DIN Rail Mount 18 A 600 VAC 48 VAC to 600 VAC 3 mA Each DRH
Phoenix Contact Contactors - Solid State Solid State Contact 24V DC 50In Stock
Min.: 1
Mult.: 1

DIN Rail Mount 20 A 42 VAC to 660 VAC 24 VDC 12 mA - 30 C + 70 C 18 mm 110 mm
Crydom Contactors - Solid State 20A 600VAC 4-32DC In ZC 2Leg 3phs DINRail 10In Stock
20Expected 08/12/2026
Min.: 1
Mult.: 1

DIN Rail Mount 20 A 600 VAC 4 VDC to 32 VDC 17 mA Each DRH
Phoenix Contact Contactors - Solid State Solid State Contact 24V DC 81In Stock
Min.: 1
Mult.: 1

DIN Rail Mount 30 A 42 VAC to 660 VAC 24 VDC 12 mA - 30 C + 70 C 18 mm 110 mm
Phoenix Contact Contactors - Solid State Solid State Contact 230V AC 1In Stock
Min.: 1
Mult.: 1

DIN Rail Mount 20 A 42 VAC to 660 VAC 230 VAC 17 mA - 30 C + 70 C 18 mm 110 mm
Phoenix Contact Contactors - Solid State Solid State Contact 24V DC 4In Stock
Min.: 1
Mult.: 1

DIN Rail Mount 50 A 42 VAC to 660 VAC 24 VDC 12 mA - 30 C + 70 C 35 mm 110 mm
Crydom Contactors - Solid State 4.8A 480VAC 3Phs 1NO+1NC EMR, RN, 3L 3In Stock
Min.: 1
Mult.: 1

DIN Rail Mount 4.8 A 480 VAC 18 VAC to 30 VAC, 18 VDC to 30 VDC 32 mA - 20 C + 60 C Each DRC3
Crydom Contactors - Solid State 20A 600VAC 4-32DC In RN 2Leg 3phs DINRai 6In Stock
Min.: 1
Mult.: 1

DIN Rail Mount 20 A 600 VAC 4 VDC to 32 VDC 17 mA Each DRH
Crydom Contactors - Solid State 18A 600AC 280A/DC In RN 3Leg 3phs DINRai 2In Stock
Min.: 1
Mult.: 1

DIN Rail Mount 18 A 600 VAC 90 VAC to 280 VAC, 90 VDC to 280 VDC 3 mA Each DRH
Crydom Contactors - Solid State 18A 600VAC 4-32DC In ZC 3Leg 3phs DINRail
3Expected 27/08/2026
Min.: 1
Mult.: 1

DIN Rail Mount 18 A 600 VAC 4 VDC to 32 VDC 17 mA Each DRH
Phoenix Contact Contactors - Solid State Solid State Contact 230V AC
6Expected 30/11/2026
Min.: 1
Mult.: 1

DIN Rail Mount 30 A 42 VAC to 660 VAC 230 VAC 17 mA - 30 C + 70 C 18 mm 110 mm
Phoenix Contact Contactors - Solid State Solid State Contact 230V AC Non-Stocked Lead-Time 8 Weeks
Min.: 1
Mult.: 1

DIN Rail Mount 50 A 42 VAC to 660 VAC 230 VAC 17 mA - 30 C + 70 C 35 mm 110 mm
Crydom Contactors - Solid State 4.8A 480VAC 3Phs 1NO+1NC EMR, ZC, 3L Non-Stocked Lead-Time 16 Weeks
Min.: 10
Mult.: 10

DIN Rail Mount 4.8 A 480 VAC 18 VAC to 30 VAC, 18 VDC to 30 VDC 32 mA - 20 C + 60 C Each DRC3
Crydom Contactors - Solid State 7.6A 480VAC 3Phs 1NO+1NC EMR, ZC, 2L Non-Stocked Lead-Time 18 Weeks
Min.: 125
Mult.: 125

DIN Rail Mount 7.6 A 480 VAC 18 VAC to 30 VAC, 18 VDC to 30 VDC 32 mA - 20 C + 60 C Each DRC3
Crydom Contactors - Solid State 7.6A 480VAC 3Phs 1NO+1NC EMR, RN, 2L Non-Stocked Lead-Time 16 Weeks
Min.: 125
Mult.: 125

DIN Rail Mount 7.6 A 480 VAC 18 VAC to 30 VAC, 18 VDC to 30 VDC 32 mA - 20 C + 60 C Each DRC3
Crydom Contactors - Solid State 7.6A 480VAC 3Phs 2NO EMR, ZC, 3L Non-Stocked Lead-Time 18 Weeks
Min.: 110
Mult.: 110

DIN Rail Mount 4.8 A 480 VAC 18 VAC to 30 VAC, 18 VDC to 30 VDC 32 mA - 20 C + 60 C Each DRC3
Crydom Contactors - Solid State 4.8A 480VAC 3Phs 2NO EMR, ZC, 2L Non-Stocked Lead-Time 18 Weeks
Min.: 130
Mult.: 130

DIN Rail Mount 7.6 A 480 VAC 18 VAC to 30 VAC, 18 VDC to 30 VDC 32 mA - 20 C + 60 C Each DRC3
Crydom Contactors - Solid State 7.6A 480VAC 3Phs 2NO EMR, RN, 3L Non-Stocked Lead-Time 18 Weeks
Min.: 110
Mult.: 110

DIN Rail Mount 4.8 A 480 VAC 18 VAC to 30 VAC, 18 VDC to 30 VDC 32 mA - 20 C + 60 C Each DRC3
Crydom Contactors - Solid State 4.8A 480VAC 3Phs 2NO EMR, RN, 2L Non-Stocked Lead-Time 18 Weeks
Min.: 130
Mult.: 130

DIN Rail Mount 7.6 A 480 VAC 18 VAC to 30 VAC, 18 VDC to 30 VDC 32 mA - 20 C + 60 C Each DRC3
Crydom Contactors - Solid State 4.8A 600VAC 3Phs 1NO+1NC EMR, ZC, 3L Non-Stocked Lead-Time 18 Weeks
Min.: 100
Mult.: 100

DIN Rail Mount 4.8 A 600 VAC 18 VAC to 30 VAC, 18 VDC to 30 VDC 32 mA - 20 C + 60 C Each DRC3
Crydom Contactors - Solid State 7.6A 600VAC 3Phs 1NO+1NC EMR, ZC, 2L Non-Stocked Lead-Time 18 Weeks
Min.: 110
Mult.: 110

DIN Rail Mount 7.6 A 600 VAC 18 VAC to 30 VAC, 18 VDC to 30 VDC 32 mA - 20 C + 60 C Each DRC3
Crydom Contactors - Solid State 4.8A 600VAC 3Phs 1NO+1NC EMR, RN, 3L Non-Stocked Lead-Time 18 Weeks
Min.: 95
Mult.: 95

DIN Rail Mount 4.8 A 600 VAC 18 VAC to 30 VAC, 18 VDC to 30 VDC 32 mA - 20 C + 60 C Each DRC3
Crydom Contactors - Solid State 7.6A 600VAC 3Phs 1NO+1NC EMR, RN, 2L Non-Stocked Lead-Time 18 Weeks
Min.: 110
Mult.: 110

DIN Rail Mount 7.6 A 600 VAC 18 VAC to 30 VAC, 18 VDC to 30 VDC 32 mA - 20 C + 60 C Each DRC3
Crydom Contactors - Solid State 7.6A 600VAC 3Phs 2NO EMR, ZC, 3L DIN Non-Stocked Lead-Time 18 Weeks
Min.: 105
Mult.: 105

DIN Rail Mount 4.8 A 600 VAC 18 VAC to 30 VAC, 18 VDC to 30 VDC 32 mA - 20 C + 60 C Each DRC3