Hall Effect Current Sensors

HARTING Hall Effect Current Sensors provide current measurement in power electronic applications. These closed-loop sensors feature a current rating of 100A to 2kA, a DC to 100kHz frequency range, and 1µs or 3µs response time. HARTING Hall Effect Current Sensors measure different kinds of currents and are ideal for use in generators, electrical drives, switch-mode power supplies, and other power electronic applications.

Results 14
Applied categories

Filters

Availability options
Select Image Part # Mfr. Description Datasheet Availability Pricing (IDR) Filter the results in the table by unit price based on your quantity. Qty. RoHS ECAD Model Current Rating Sensor Type Output Type Frequency Range Accuracy Supply Voltage - Min Supply Voltage - Max Response Time Minimum Operating Temperature Maximum Operating Temperature
HARTING Current Sensors – Industrial Current Sensor 200A with Spring Clamp Terminal, small - HCM200A Small Non-Stocked
Rp1.730.945
Rp1.459.975
Rp1.356.870
Rp1.236.704
Rp1.208.084
Min.: 1
Mult.: 1
HARTING Current Sensors – Industrial Current Sensor 300A Ind. with Cable Non-Stocked
Rp3.222.291
Rp2.718.143
Rp2.526.244
Rp2.377.642
Min.: 1
Mult.: 1
300 A Closed Loop 150 mA 0 Hz to 100 kHz 0.5 % 15 V 24 V 1 us - 40 C + 85 C
HARTING Current Sensors – Industrial Current Sensor 500A Railw.w.feet+cable Non-Stocked
Rp4.935.257
Rp4.163.992
Rp3.869.722
Rp3.848.257
Min.: 1
Mult.: 1
500 A Closed Loop 125 mA 0.6 % 15 V 24 V 1 us - 40 C + 85 C
HARTING Current Sensors – Industrial Current Sensor 500A Railway W/Cbl Non-Stocked
Rp4.374.237
Rp3.690.665
Rp3.429.785
Rp3.410.888
Min.: 1
Mult.: 1
500 A Closed Loop 125 mA 0.1 % 15 V 24 V 1 us - 40 C + 85 C
HARTING Current Sensors – Industrial Current Sensor 1000A Ind. W/Cbl Non-Stocked
Rp3.880.729
Rp3.274.027
Rp3.062.314
Rp3.003.791
Min.: 1
Mult.: 1
1 kA Closed Loop 200 mA 0 Hz to 100 kHz 0.4 % 15 V 24 V 1 us - 40 C + 85 C
HARTING Current Sensors – Industrial Current Sensor 1000A Railw. w.cable Non-Stocked
Rp4.919.480
Rp4.150.599
Rp3.857.247
Rp3.835.965
Min.: 1
Mult.: 1
1 kA Closed Loop 200 mA 0.4 % 15 V 24 V 1 us - 40 C + 85 C
HARTING Current Sensors – Industrial Current Sensor 2000A railway w. cable Non-Stocked
Rp7.050.184
Rp5.947.957
Rp5.913.283
Min.: 1
Mult.: 1
2 kA Closed Loop 33 mA 0 Hz to 100 kHz 0.3 % 15 V 24 V - 40 C + 85 C
HARTING Current Sensors – Industrial ECO current sensor HCSE 100 Non-Stocked
Rp2.025.031
Rp1.708.013
Rp1.587.479
Rp1.452.820
Rp1.448.600
Min.: 1
Mult.: 1
100 A Closed Loop 0 Hz to 100 kHz 1 % 3 us - 25 C + 85 C
HARTING Current Sensors – Industrial ECO current sensor HCSE 300 Non-Stocked
Rp2.025.031
Rp1.708.013
Rp1.587.479
Rp1.452.820
Rp1.448.600
Min.: 1
Mult.: 1
300 A Closed Loop 0 Hz to 100 kHz 1 % 3 us - 25 C + 85 C
HARTING Current Sensors – Industrial ECO current sensor HCSE 500 Non-Stocked
Rp1.735.532
Rp1.577.022
Rp1.516.664
Rp1.449.517
Rp1.448.600
Min.: 1
Mult.: 1
500 A Closed Loop 0 Hz to 100 kHz 1 % 3 us - 25 C + 85 C
HARTING Current Sensors – Industrial ECO current sensor HCSE 800 Non-Stocked
Rp1.696.088
Rp1.635.729
Rp1.560.878
Rp1.541.614
Min.: 1
Mult.: 1
800 A Closed Loop 0 Hz to 100 kHz 1 % 3 us - 25 C + 85 C
HARTING Current Sensors – Industrial Current Sensor Han Open Loop 2000Amps, rectangular - HCME2000 Non-Stocked
Rp4.226.001
Min.: 1
Mult.: 1
HARTING Current Sensors – Industrial Current Sensor Han Open Loop 2500Amps, rectangular - HCME2500 Non-Stocked
Rp4.578.978
Min.: 1
Mult.: 1
HARTING 20311008201
HARTING Current Sensors – Industrial Current Sensor 1000A Railw. w.foot+cable Non-Stocked
Rp5.738.078
Rp4.841.142
Rp4.499.173
Rp4.474.222
Min.: 1
Mult.: 1